The cartridge heater CLD( low density) (up to 5 watts / cm2), is a conventional heating element, usually when working conditions are not particularly severe. In the LD Resistors, Coil nickel-chromium is contained within a base ceramic mass is surrounded with magnesium-oxide powder, which also fills all the internal spaces of the insulator core.
Diameter (metric & imperial sizes) and Tollerances
|
||||||||||
Ø
|
6,5
|
8
|
10
|
12,5
|
16
|
20
|
1/4"
|
3/8"
|
1/2"
|
5/8"
|
Tollerance
|
-0,03 | -0,04 | -0,04 | -0,05 | -0,05 | -0,06 | -0,03 | -0,04 | -0,05 | -0,05 |
-0,05 | -0,06 | -0,07 | -0,08 | -0,08 | -0,1 | -0,05 | -0,07 | -0,08 | -0,05 | |
Length Tollerance
|
Relative ±1,5% | |||||||||
Absolute ±1mm (minimum) | ||||||||||
Cold insolution Resistance 500 V-DC
|
≥ 10 MΩ | |||||||||
Dielectric Strength
|
1500 V | |||||||||
Maximum leakage current (cold)
|
≤ 0,5 mA | |||||||||
Cold Wattage Tollerance
|
±10% | |||||||||
Maximum Power Density
|
10 W/cm2 | |||||||||
Unheated Zones Length
|
Cables Zone from 15 to 25 mm | |||||||||
Bottom Disc Zone nearly 5 mm | ||||||||||
Maximum Working Temperature
|
400ºC on the external sheath |